Measuring principle
Differential pressure
-
Characteristic
Specialist with one or two capillaries for accurate differential pressure measurement.
Intuitive and clear wizards for commissioning, proof tests and verification. -
Supply voltage
Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC -
Reference Accuracy
Standard:
up to 0.1 % -
Long term stability
0.025 % of URL/ year
0.05 % of URL/ 5 years
0.10 % of URL/ 10 years -
Process temperature
-70°C...+400°C
(-x°F...+752°F) -
Ambient temperature
-40°C...+85°C
(-40°F...+185°F) -
Measuring cell
100 mbar...40 bar
(1.5 psi...600 psi) -
Smallest calibratable span
5 mbar (0.075 psi)
-
Vacuum resistance
50 mbar (0.73 psi)
-
Max. Turn down
100:1
-
Max. overpressure limit
160 bar
(2400 psi) -
Process connection
Thread: MNPT1/2, G1/2
Flange: NPS 2"...4", DN50...100 -
Material process membrane
316L, AlloyC,
Tantal,
Monel
PTFE
Gold -
Material gasket
PTFE, FKM,
EPDM, FFKM -
Fill fluid
Silicone oil,
inert oil,
vegetable oil,
low- / high temperature oil -
Material housing
Aluminium, 316L
-
Communication
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional) -
Certificates / Approvals
ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
-
Safety approvals
SIL
-
Design approvals
EN10204-3.1,
NACE MR0175,
NACE MR0103 -
Specialities
Heartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM
Deltabar PMD78B – Differential Pressure Transmitter
Field of application
This transmitter belongs to the new Deltabar generation. The device is robust and can be remotely controlled via SmartBlue App using a secure Bluetooth connection. It allows condition based maintenance to increase plant availability.
The software is designed to simplify the handling. Intuitive wizards guide the user through setup, proof tests and verification of the device.
Heartbeat Technology offers verification and monitoring functions to detect unwanted anomalies e.g. plugged impulse lines.
-
Pressure measuring ranges up to 40 bar (600 psi)
-
Process temperatures up to 400 °C (752 °F) with diaphragm seal
-
Static pressure: up to 160 bar (2400 psi)
-
Accuracy: up to +/- 0.075%
Benefits
-
Wireless control of the device in hard to reach areas with the SmartBlue App and a Bluetooth® connection
-
Reduce systematic failures – error free SIL commissioning and instrument guided proof testing
-
With Heartbeat Technology you are able to verify the health of the device while the process is running. This increases plant availability.
-
Simple indication of device status – display changes from green to red when diagnostic messages occur