Measuring principle
Differential pressure
-
Characteristic
Transmitter with metal membrane for differential pressure monitoring in liquids or gases.
Intuitive and clear wizard for commissioning -
Supply voltage
Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC -
Reference Accuracy
Standard:
up to 0.075 %
Platinum:
up to 0.055 % -
Long term stability
0.05 % of URL/ year
0.13 % of URL/ 5 years
0.23 % of URL/ 10 years -
Process temperature
-40°C...+110°C
(-40°F...+230°F) -
Ambient temperature
-40°C...+85°C
(-40°F...+185°F) -
Measuring cell
30 mbar...40 bar
(0.45 psi...600 psi) -
Smallest calibratable span
0.3 mbar (0.0045 psi)
-
Vacuum resistance
25 mbar (0.0375 psi)
-
Max. Turn down
100:1
-
Max. overpressure limit
250 bar (3750 psi)
-
Process connection
NPT1/4-18,
RC1/4" -
Material process membrane
316L, AlloyC
-
Material gasket
PTFE, FKM, EPDM, FFKM
-
Fill fluid
Silicone oil,
Inert oil -
Material housing
Aluminium
-
Communication
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional) -
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI
-
Safety approvals
SIL
-
Design approvals
EN10204-3.1,
NACE MR0175,
NACE MR0103 -
Drinking water approvals
NSF, KTW
-
Specialities
Bluetooth® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Deltabar PMD55B – Differential Pressure Transmitter
Field of application
This transmitter belongs to the new Deltabar generation. It is robust and easy to operate either locally or remotely. The transmitter can be controlled wireless via app on a mobile device using a secure Bluetooth connection. The PMD55B allows condition-based maintenance which increases efficiency in technical service significantly.
The software is designed to simplify the handling. Intuitive wizards guide you through the setup and proof testing of the device which minimizes operating errors.
-
Pressure measuring range: up to 40 bar (600 psi)
-
Static pressure up to 250bar (3750psi)
-
Accuracy: up to +/-0.055%
Benefits
-
Wireless control of the device in the process area with the SmartBlue App without interrupting the process
-
Reduce on site accidents and protect equipment when instruments are in difficult to reach areas
-
Reduce systematic failures – error free SIL commissioning and instrument guided proof testing