Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.
- Simple, low-cost installation: able to measure and display without auxiliary power supply
- Unique modularity and serviceability: Limit switches, 2-wire 4…20mA, totalizer with LCD and pulse output, fieldbus interfaces
- NE 107 device and application diagnostics with CFM (Continuous Float Monitoring), e.g. for float blockade detection
- Universal ex-concept: Explosion proof and intrinsically safe
- Various stainless steel and alloy sensor materials
- Optional stainless steel housing for corrosive atmospheres
- Ingress protection IP66 and IP68 / NEMA4X and NEMA6, IP69K optional
- Full scale value for liquids: 10…120,000 l/h / 5…32,000 GPH
- Full scale value for gases: 0.7…2800 m3/h / 25…100,000 SCFH
- Turndown ratio 10:1 (optional 100:1)
- Maximum measuring error: ±1.6% (acc. to VDI/VDE 3513-2) or ±1.5% of full scale
- Suitable for use in Safety Instrumented Systems with SIL 2, in redundant design (1oo2) also in SIL 3 applications (type A device)
- Optional hygienic design for use in the food and pharmaceutical industry